units ¶You invoke units like this:
units [options] [from-unit [to-unit]]
If the from-unit and to-unit are omitted, the program
will use interactive prompts to determine which conversions to perform.
See Interacting with units.
If both from-unit and to-unit are given, units will
print the result of that single conversion and then exit.
If only from-unit appears on the command line, units will
display the definition of that unit and exit.
Units specified on the command line may need
to be quoted to protect them from shell interpretation and to group
them into two arguments. Note also that the --quiet option
is enabled by default if you specify from-unit on the command line.
See Using units Non-Interactively.
The default behavior of units can be changed by various
options given on the command line. In most cases, the options may be
given in either short form (a single ‘-’ followed by a single
character)
or long form (-- followed by a word or hyphen-separated words).
Short-form options are cryptic but require
less typing; long-form options require more typing but are more
explanatory and may be more mnemonic. With long-form options you need
only enter sufficient characters to uniquely identify the option to
the program. For example, --out %f works, but
--o %f fails because units has other long options
beginning with ‘o’. However, --q works because
--quiet is the only long option beginning with ‘q’.
Some options require arguments to specify a value (e.g., -d 12 or --digits 12). Short-form options that do not take arguments may be concatenated (e.g., -erS is equivalent to -e -r -S); the last option in such a list may be one that takes an argument (e.g., -ed 12). With short-form options, the space between an option and its argument is optional (e.g., -d12 is equivalent to -d 12). Long-form options may not be concatenated, and the space between a long-form option and its argument is required. Short-form and long-form options may be intermixed on the command line. Options may be given in any order, but when incompatible options (e.g., --output-format and --exponential) are given in combination, behavior is controlled by the last option given. For example, -o%.12f -e gives exponential format with the default eight significant digits).
Many options can be set interactively; this can be especially helpful
for Windows users who start units from a shortcut.
See Setting Options Interactively for more information.
The following options are available:
-c ¶--checkCheck that all units and prefixes defined in units data files reduce to
primitive units. Display a list of all units that cannot be reduced and
a list of units with circular definitions. Also display some other
diagnostics about suspicious definitions in the units data file. Only
definitions active in the current locale are checked. You should always
run units with this option after modifying a units data file.
Some errors may hide other errors, so you should run units
with this option again after correcting any errors, and keep doing so
until there are no errors.
--check-verbose ¶--verbose-checkLike the --check option, this option displays a list of units that
cannot be reduced. But it also lists the units as they are checked.
Because the --check option now catches circular unit
definitions that previously caused units to hang, this option
is no longer necessary. It is retained only for compatibility with
previous versions.
--list-units ¶This option displays a list of all units and exits. With output
redirected to a file, it can produce a list of all units in the
database, which may comprise multiple units data files. It
can also be useful if you aren’t sure of the name of a unit or want to find
all units of a particular type and you want a more advanced search than
is available with the interactive search command.
See Finding Units for some examples of how this option can be used.
-d ndigits ¶--digits ndigitsSet the number of significant digits in the output to the value
specified (which must be greater than zero). For example,
-d 12 sets the number of significant digits to 12.
With exponential output, units displays one digit to the left
of the decimal point and eleven digits to the right of the decimal point.
On most systems, the maximum number of internally meaningful digits is
15; if you specify a greater number than your system’s maximum, units
will print a warning and set the number to the largest meaningful
value. To directly set the maximum value, give an argument
of max (e.g., -d max). Be aware, of course, that
“significant” here refers only to the display of numbers; if
results depend on physical constants not known to this precision, the
physically meaningful precision may be less than that shown. The
--digits option is incompatible with the --output-format
option; if you give them both, the format is controlled by the last
option given.
-e ¶--exponentialSet the numeric output format to exponential (i.e., scientific
notation), like that used in the Unix units program.
The default precision is eight significant digits (seven digits to the
right of the decimal point); this can be changed with the
--digits option. The --exponential
option is incompatible with the --output-format option; if you
give them both, the format is controlled by the last option given.
-o format ¶--output-format formatThis option affords complete control over the numeric output format
using the specified format. The format is a single floating
point numeric format for the printf function in the
C programming language. All compilers support the format types ‘g’
and ‘G’ to specify significant digits, ‘e’ and ‘E’ for
scientific notation, and ‘f’ for fixed-point decimal.
The ISO C99 standard introduced the ‘F’ type for fixed-point
decimal and the ‘a’ and ‘A’ types for hexadecimal
floating point; these types are allowed with compilers that support
them. The default format is ‘%.8g’; for greater precision, you
could specify -o %.15g. Unlike with the --digits
option, you can specify any desired precision, though not all digits may
be meaningful. See Numeric Output Format, and the documentation for
printf for more detailed descriptions of the format
specification. The --output-format option affords the greatest
control of the output appearance, but requires at least rudimentary
knowledge of the printf format syntax. If you don’t want to
bother with the printf syntax, you can specify greater precision
more simply with the --digits option or select exponential
format with --exponential. The --output-format option
is incompatible with the --exponential and --digits
options; if you give either in combination with --output-format,
the format is controlled by the last option given.
-f filename ¶--file filenameInstruct units to load the units file filename. You
can specify up to 25 units files on the command line. When you use
this option, units will load only the files you list
on the command line; it will not load the standard file or your
personal units file unless you explicitly list them. If filename
is the empty string (-f ""), the default main units file (or
that specified by UNITSFILE) will be loaded in addition to any
others specified with -f.
-L logfile ¶--log logfileSave the results of calculations in the file logfile; this can be
useful if it is important to have a record of unit conversions or other
calculations that are to be used extensively or in a critical activity
such as a program or design project. If logfile exits, the new
results are appended to the file.
This option is ignored when units is used non-interactively.
See Logging Calculations, for a more detailed description and some
examples.
-H filename ¶--history filenameInstruct units to save history to filename, so that a
record of your commands is available for retrieval across different
units invocations. To prevent the history from being saved
set filename to the empty string (-H ""). This
option has no effect if readline is not available.
-h ¶--helpPrint out a summary of the options for units.
-m ¶--minusCauses ‘-’ to be interpreted as a subtraction operator. This is the default behavior.
-p ¶--productCauses ‘-’ to be interpreted as a multiplication operator when it has two operands. It will act as a negation operator when it has only one operand: ‘(-3)’. By default ‘-’ is treated as a subtraction operator.
--oldstar ¶Causes ‘*’ to have the old-style precedence, higher than the precedence of division so that ‘1/2*3’ will equal ‘1/6’.
--newstar ¶Forces ‘*’ to have the new (default) precedence that follows the usual rules of algebra: the precedence of ‘*’ is the same as the precedence of ‘/’, so that ‘1/2*3’ will equal ‘3/2’.
-r--roundWhen converting to a combination of units given by a unit list, round the value of the last unit in the list to the nearest integer.
-S--show-factorWhen converting to a combination of units specified in a list, always show a non-unity factor before a unit that begins with a fraction with a unity denominator. By default, if the unit in a list begins with fraction of the form 1|x and its multiplier is an integer other than 1, the fraction is given as the product of the multiplier and the numerator (e.g., ‘3|8 in’ rather than ‘3 * 1|8 in’). In some cases, this is not what is wanted; for example, the results for a cooking recipe might show ‘3 * 1|2 cup’ as ‘3|2 cup’. With the --show-factor option, a result equivalent to 1.5 cups will display as ‘3 * 1|2 cup’ rather than ‘3|2 cup’. A user-specified fractional unit with a numerator other than 1 is never overridden, however—if a unit list specifies ‘3|4 cup;1|2 cup’, a result equivalent to 1 1/2 cups will always be shown as ‘2 * 3|4 cup’ whether or not the --show-factor option is given.
--conformable ¶In non-interactive mode, show all units conformable with the original
unit expression. Only one unit expression is allowed; if you give more
than one, units will exit with an error message and return
failure.
-v ¶--verboseGive slightly more verbose output when converting units. When combined with the -c option this gives the same effect as --check-verbose. When combined with --version produces a more detailed output, equivalent to the --info option.
-V ¶--versionPrint the program version number, tell whether the readline
library has been included, tell whether UTF-8 support has been included;
give the locale, the location of the default main units data file, and
the location of the personal units data file; indicate if the personal
units data file does not exist.
When given in combination with the --terse option, the program prints only the version number and exits.
When given in combination with the --verbose option, the program, the --version option has the same effect as the --info option below.
-I ¶--infoPrint the information given with the --version option, show the
pathname of the units program, show the status of the UNITSFILE
and MYUNITSFILE environment variables, and additional information
about how units locates the related files. On systems running
Microsoft Windows, the status of the UNITSLOCALE environment
variable and information about the related locale map are also given.
This option is usually of interest only to developers and
administrators, but it can sometimes be useful for troubleshooting.
Combining the --version and --verbose options has the same effect as giving --info.
-U ¶--unitsfilePrint the location of the default main units data file and exit; if the file cannot be found, print “Units data file not found”.
-u units-system ¶--units units-systemSpecify a CGS units system or natural units system. The supported units systems are: gauss[ian], esu, emu, hlu, natural, natural-gauss, hartree, planck, planck-red, and si. See Alternative Unit Systems, for further information about these unit systems.
-l locale ¶--locale localeForce a specified locale such as ‘en_GB’ to get British definitions by default. This overrides the locale determined from system settings or environment variables. See Locale, for a description of locale format.
-n--nolistsDisable conversion to unit lists.
-s ¶--strictSuppress conversion of units to their reciprocal units. For
example, units will normally convert hertz to seconds
because these units are reciprocals of each other. The strict option
requires that units be strictly conformable to perform a conversion, and
will give an error if you attempt to convert hertz to seconds.
-1 ¶--one-lineGive only one line of output (the forward conversion); do not print
the reverse conversion. If a reciprocal conversion is
performed, then units will still print the “reciprocal
conversion” line.
-t ¶--tersePrint only a single conversion factor without any clutter, or if you
request a definition, prints just the definition (including its units).
This option can be used when calling units from another
program so that the output is easy to parse.
The command units --terse mile m produces the output ‘1690.344’.
This option has the combined
effect of these options: --strict --quiet --one-line
--compact. When combined with --version it produces
a display showing only the program name and version number.
--compact ¶Give compact output featuring only the conversion factor; the multiplication and division signs are not shown, and there is no leading whitespace. If you convert to a unit list, then the output is a semicolon separated list of factors. This turns off the --verbose option.
-q ¶--quiet--silentSuppress the display of statistics about the number of units loaded,
any messages printed by the units database,
and the prompting of the user for units. This option does not
affect how units displays the results. This option is
turned on by default if you invoke units with a unit